NTC Stromerzeuger 15 kVA, Honda GX690, MECC ALTE, E-Start
€4,188.60
Equipment
- Honda GX 690 engine
- MECC ALTE generator
- Electric start
- Three-phase output 15 kVA
- Two single-phase outputs, each 5 kVA
Technical data
| Manufacturer | NTC |
|---|---|
| Product type | Petrol generator |
| Three-phase output | 15 kVA (400 V) |
| Single-phase output | 2 × 5 kVA (230 V) |
| Engine | Honda GX 690 |
| Engine design | 2-cylinder, 4-stroke OHV, 90° V-twin |
| Displacement | 688 cm³ |
| Net engine power | 16,5 kW (22,1 PS) at 3.600 min⁻¹ |
| Continuous engine power | 13,0 kW at 3.600 min⁻¹ |
| Cylinder liners | Cast iron |
| Ignition system | Digital CDI with variable ignition timing |
| Carburettor | Twin carburettor with solenoid valve |
| Lubrication | Full-pressure lubrication |
| Engine oil capacity | 1,7 l |
| Fuel consumption | 6,7 l/h at continuous output |
| Generator | MECC ALTE, Italy |
| Starting | Electric |
Product description
Generator with Honda engine and MECC ALTE generator
The unit delivers 15 kVA three-phase and also provides two single-phase outputs, each rated at 5 kVA. It is powered by the Honda GX 690, a 688 cm³ twin-cylinder V-twin with electric start.
The choice of components – where quality is determined
With generators, the power rating says little about service life. The engine and generator make the difference.
| Component | What it offers |
|---|---|
| Honda GX 690 | Industrial engine for continuous operation, with spare parts available worldwide |
| MECC ALTE | Italian generator specialist, an industry standard |
Why this matters when choosing what to buy: A generator may sit unused for years – and then need to work exactly as required. Or it may run for eight hours a day on a building site. Both situations call for proven technology.
The practical advantage when it comes to spare parts: Filters, spark plugs and wear parts for the Honda GX 690 are available from any garden machinery dealer. With no-name engines, this is often no longer the case after a few years.
The Honda GX 690 in detail
This is an industrial engine, not a garden machinery engine.
- Two cylinders in a V configuration – smoother running and less vibration than a single-cylinder engine of the same power.
- Cast-iron cylinder liners – considerably more wear-resistant than coated aluminium cylinder surfaces.
- Full-pressure lubrication – all bearing points are actively supplied with oil, rather than relying solely on splash lubrication.
- Digital CDI ignition with variable ignition timing for high power output and cleaner combustion.
- Twin carburettor – consistent fuel-air mixture preparation for both cylinders.
Why full-pressure lubrication is particularly important in a generator: A generator runs for hours at a constant speed under load. This places greater demands on the oil circuit than variable-speed operation – the bearing points get no periods of relief.
15 kVA three-phase and 2 × 5 kVA single-phase – what this means
This is often misunderstood.
How the output is divided: A 15 kVA three-phase generator distributes its output across three phases – that is, 5 kVA per phase. Two of these phases are also brought out as 230 V outputs.
What this means:
- The total output remains 15 kVA. Three-phase and single-phase loads cannot be added together.
- Each single-phase output provides 5 kVA – no more.
- When using outputs simultaneously their combined load must be taken into account.
Why two single-phase outputs are useful: On a building site, generators rarely supply only three-phase equipment. Lighting, power tools, dehumidifiers and coffee machines run on 230 V.
Two separate outputs allow the load to be distributed – rather than drawing everything from one phase and overloading it while the others are left unused.
Unbalanced load – a practical consideration
A factor that affects service life.
What happens when the load is unevenly distributed: If only one phase is heavily loaded, the generator runs unbalanced. The loaded winding heats up while the others remain cool – and the voltage on the unloaded phases rises.
The result: Equipment connected to lightly loaded phases may be exposed to overvoltage. This can cause real damage to sensitive electronics.
What this means: Distribute loads as evenly as possible across the available outputs. The two single-phase outputs are designed for exactly this purpose.
Electric start
The unit is started using a key or button.
Why this matters with an engine of this size: A 688 cm³ twin-cylinder engine can be started by hand – the GX 690 has an automatic decompression system to help with this. However, doing so in cold weather, after a long period out of use or several times a day is no pleasure.
Another consideration: Electric start means the unit can in principle also be started remotely or integrated into an automatic standby power system – check with the manufacturer whether this model is equipped for this.
Fuel consumption – a calculation for planning
| Consumption at continuous output | 6,7 l/h |
|---|---|
| At 8 hours at full load | approx. 54 l |
Important context: This figure is for full engine output. Consumption is considerably lower at partial load – a generator running at 40% load uses significantly less fuel.
When calculating running time the tank capacity is the key factor. For continuous use on building sites, an external fuel supply or an auxiliary tank is often more practical than refuelling several times.
What 15 kVA is enough for
| Application | Typical requirement |
|---|---|
| Power supply for hand tools on building sites | 3 – 8 kVA |
| Circular saw, masonry saw, mixer | 5 – 10 kVA |
| Dehumidifiers and heaters | 2 – 5 kVA each |
| Standby power for farm and livestock buildings | depending on installation |
| Event equipment | depending on set-up |
A point often overlooked when sizing a generator: Motors have a starting current several times higher than their rated current. A 4 kW motor can briefly draw 15 to 25 kVA when starting – the generator must be able to handle this.
For applications involving several large motors consult a specialist supplier when sizing the generator.
Applications
Building sites and construction companies, tradespeople, agriculture and standby power, event equipment, agricultural contractors, local authorities and council depots, civil protection and fire services, equipment hire, markets and outdoor applications.
Operating instructions
- Observe the total output of 15 kVA – three-phase and single-phase loads cannot be added together.
- Distribute loads as evenly as possible across the outputs; avoid unbalanced loading.
- Allow for motor starting currents – these are several times higher than the rated current.
- Only operate the unit outdoors or in well-ventilated areas – internal combustion engines produce exhaust gases containing carbon monoxide.
- Never operate in enclosed spaces, garages or cellars.
- Set up on level, firm ground.
- Refuel only when the engine is switched off and cool, away from sources of ignition.
- Check the oil level before every start; oil capacity 1,7 l.
- When connecting to a building installation, observe the requirements for mains isolation – feeding electricity back into the public grid is life-threatening and must be prevented using suitable changeover equipment.
- Electrical work on the building installation must only be carried out by a qualified electrician.
- Use extension leads with an adequate rating; long leads cause voltage drop.
- Protect the unit from moisture; observe its ingress protection rating.
- Follow the engine manufacturer's maintenance intervals.
- For extended periods out of use, drain or stabilise the fuel.
Frequently asked questions
Can I draw 15 kVA and 2 × 5 kVA at the same time?
No. The generator's total output is 15 kVA – the outputs share this capacity. Each single-phase output provides 5 kVA.
Which engine is fitted?
A Honda GX 690 – a 688 cm³ twin-cylinder V-twin with cast-iron cylinder liners, full-pressure lubrication and digital CDI ignition.
Who are MECC ALTE?
An Italian generator manufacturer regarded as an industry standard. The combination of a branded engine and branded generator is a mark of quality.
How much fuel does the unit use?
At continuous output, the engine uses around 6,7 l/h. Consumption is considerably lower at partial load.
Why are there two single-phase outputs?
To distribute the load. If all 230 V equipment is connected to one phase, this creates an unbalanced load – the loaded winding heats up, and the voltage on lightly loaded phases may rise.
Can the unit be used as a standby generator?
In principle, yes. However, connecting it to a building installation requires changeover equipment that reliably prevents electricity from being fed back into the grid – installation must be carried out by a qualified electrician.
Can I operate the unit indoors?
No. Internal combustion engines produce exhaust gases containing carbon monoxide. Operating the unit in enclosed spaces, garages or cellars is life-threatening.
Does the unit have electric start?
Yes, it has electric start. This is a considerable advantage with a 688 cm³ twin-cylinder engine, particularly in cold weather and when starting several times a day.
| Drive type: | Benzinmotor |
|---|---|
| Engine manufacturer: | Honda |
| Gerätetyp : | Stromaggregat |
| Maximalleistung: | 15 kVA |
| Spannungsregelung AVR: | ohne |
| Startsystem : | Elektrostart |
| Stromart: | 3-phasig (400 V) |