NTC Stromerzeuger 14 kVA, 400/230 V, Honda-Motor, E-Start
€3,790.00
Features
- Honda GX 630 petrol engine with electric start
- Connections: 1 × 400 V and 2 × 230 V
- Compound voltage regulation
- Open frame with access to all service points
- Vibration isolation between the frame and the engine-generator unit
Technical data
| Manufacturer | NTC STAVEBNÍ TECHNIKA spol. s r.o. |
|---|---|
| Product type | Generator, three-phase |
| Electrical output, 3-phase | 14,0 kVA |
| Electrical output, 1-phase | 4,0 kVA |
| Current, 3-phase / 1-phase | 20,0 A / 20,0 A |
| Voltage | 400 V / 230 V |
| Frequency | 50 Hz |
| Connections | 1 × 400 V + 2 × 230 V |
| Voltage regulation | Compound |
| Engine | Honda GX 630 |
| Engine net power | 15,5 kW at 3.600 min⁻¹ (according to SAE J1349) |
| Electric start | yes |
| Dimensions (L × W × H) | 1.060 × 660 × 600 mm |
| Weight | 114 kg |
| Quality management | ISO 9001:2015 |
| Country of manufacture | Czech Republic |
Product description
Three-phase generator with 14 kVA
The unit supplies both single-phase and three-phase loads, including circular saws and machines with what is known as a high starting load. The Honda petrol engine is started electrically.
Compound regulation – the key point
The manufacturer describes this as a particularly effective method of voltage regulation, especially for equipment such as compressors, water pumps and circular saws.
What is different about these loads: They have a high starting current. An electric motor draws several times its rated current when starting – depending on the design, five to eight times as much.
What happens with poor regulation: The voltage drops, the motor fails to get up to speed and, in the worst case, remains stalled – putting corresponding strain on the winding.
Compound regulation works differently: It uses the current flowing to strengthen the excitation field. The higher the load, the stronger the excitation – the generator counteracts the voltage drop.
Compound or AVR – the choice
NTC offers both types of regulation. The choice depends on the load.
| Compound (this version) | AVR | |
|---|---|---|
| Strength | high starting currents | constant voltage |
| Suitable for | compressors, pumps, circular saws, compactors | electronics, chargers, sensitive equipment |
| Response to load peaks | increases excitation | adjusts afterwards |
| Voltage accuracy | adequate | higher |
The rule of thumb when advising customers: If you are running machines with motors, choose Compound. If you are powering electronics – control systems, chargers, measuring equipment – choose AVR.
The same output level is available in an AVR version – with the same engine and weight.
14 kVA three-phase, but only 4 kVA single-phase
This is the point most often overlooked.
| Three-phase (400 V) | 14,0 kVA at 20,0 A |
|---|---|
| Single-phase (230 V) | 4,0 kVA at 20,0 A |
Why the single-phase figure is so much lower: The generator produces three phases. A 230 V load is connected to just one of them – the other two remain unused.
What this means: If you mainly run 230 V equipment, you only get 4 kVA from a 14 kVA unit. For single-phase use only, a single-phase generator would be a more suitable and cheaper choice.
This unit is worthwhile when you have genuine three-phase loads – circular saws, concrete mixers, pumps and hoists.
The Honda GX 630
The engine delivers 15,5 kW at 3.600 min⁻¹ according to SAE J1349.
Why the engine output is higher than the electrical output: 14 kVA electrical output corresponds to around 11 kW of active power at a typical power factor. The remainder is accounted for by generator losses and the reserve for starting peaks.
Why the GX series is a good choice: It has been widely used in the construction industry for decades – spare parts, servicing and wear parts are readily available nationwide. For a unit used on different building sites, this is a real advantage over niche engines.
Electric start
The unit is started using a starter motor, unlike the smaller models in the range.
Why this is necessary at this size: A V-twin engine of almost 700 cm³ is difficult to start by hand and requires considerable effort. In cold weather and after being left unused for a long time, this becomes a real ordeal.
For hire companies and businesses with different operators electric start is the more practically important feature: if it is easy to start, it will be used.
Vibration isolation
A flexible connection is fitted between the frame and the engine-generator unit.
What it does: It reduces the vibration transmitted to the supporting surface.
Why this is more than just a comfort feature:
- The unit stays in place. A generator mounted rigidly can move noticeably across the floor over several hours.
- Less material fatigue in the frame and welds.
- Less strain on the connections and internal wiring.
- Quieter – vibration on concrete creates structure-borne noise.
The open frame
This design has been chosen deliberately.
What it does: All service points are accessible – oil drain, air filter, spark plugs and fuel tap.
Why this matters on building sites: A generator used on site operates in dusty conditions and under continuous load. Air filter cleaning and oil changes are not annual maintenance tasks, but regular jobs – anything that is difficult to access is likely to be neglected.
The frame also provides handling points and protects the unit during transport and manoeuvring.
The connections
| Connection | Quantity | Typical loads |
|---|---|---|
| 400 V | 1 | circular saw, concrete mixer, pump, hoist |
| 230 V | 2 | hand tools, lighting, compactor |
In practice, this means: The main machine runs via the three-phase connection, while two 230 V devices can be used at the same time – as long as the single-phase output does not exceed 4 kVA.
114 kilograms – plan for transport
At 1.060 × 660 × 600 mm, the unit cannot be carried by one person.
What this means: You should have a solution for transporting and moving the unit around the building site. The manufacturer offers a wheel kit as an option – an obvious addition if the unit is used at different locations.
Available options
| Option | Benefit |
|---|---|
| Wheel kit | Moving around the building site |
| Circuit breaker | Overload protection |
| Voltmeter | Voltage monitoring |
| Hour meter | Maintenance intervals, hire billing |
| Automatic START-STOP panel | Emergency power function in the event of a mains failure |
| Metal fuel can | specifically for GX 630 and GX 690 |
The START-STOP panel is the most interesting option: It starts the generator automatically in the event of a mains failure and stops it when the mains supply returns. This turns the building-site generator into an emergency power supply – a separate use case for businesses with critical equipment.
Applications
Building sites without a mains connection, construction companies and tradespeople, event technology, agriculture and forestry, local authorities and public works depots, emergency power supply, equipment hire, mobile workshops.
Operating notes
- Note the single-phase output of 4,0 kVA – it is significantly lower than the three-phase output.
- Take account of the starting currents of connected equipment; motors draw several times their rated current.
- Only operate outdoors or in well-ventilated areas – combustion engines produce exhaust gases containing carbon monoxide.
- Do not set up in enclosed spaces, cellars or garages.
- Set up on level, load-bearing ground and secure against slipping.
- Keep away from combustible materials.
- Refuel only when the engine is switched off and cool, away from sources of ignition.
- Protect electrical connections from moisture; check cables for damage.
- When using as a standby power supply, observe the requirements for disconnection from the mains – feeding power back into the mains is life-threatening.
- Check the oil level before each use; follow the engine manufacturer's maintenance intervals.
- Clean the air filter more frequently when operating in dusty conditions.
- For prolonged storage, drain the fuel or add a stabiliser.
- Follow the manufacturer's operating instructions.
Frequently asked questions
How much power do I get in single-phase mode?
4,0 kVA at 230 V. The 14,0 kVA rating applies only to three-phase loads – a 230 V device is connected to just one of the three phases.
What is Compound regulation?
A voltage regulation system that uses the current flowing to strengthen the excitation field. The higher the load, the stronger the excitation – particularly effective for compressors, water pumps and circular saws with high starting currents.
Compound or AVR – which is better?
It depends on the load. Compound is for machines with motors and high starting currents; AVR is for electronics and equipment that needs a constant voltage.Both versions are available in this output class.
What connections does the unit have?
One 400 V connection and two 230 V connections.
Does the unit have electric start?
Yes. Electric start is practically essential for an engine of this size – starting it by hand would require considerable effort.
How heavy is the generator?
114 kg, with dimensions of 1.060 × 660 × 600 mm. A wheel kit is available as an option.
Can I use the unit as an emergency power supply?
With the optional automatic START-STOP panel, the generator starts automatically in the event of a mains failure. The requirements for disconnection from the mains must be observed.
Which engine is fitted?
A Honda GX 630 with an output of 15,5 kW at 3.600 min⁻¹ according to SAE J1349. The GX series is widely used in the construction industry – spare parts and servicing are readily available nationwide.
| Drive type: | Benzinmotor |
|---|---|
| Engine manufacturer: | Honda |
| Gerätetyp : | Stromaggregat |
| Maximalleistung: | 14 kVA |
| Spannungsregelung AVR: | ohne |
| Startsystem : | Elektrostart |
| Stromart: | 3-phasig (400 V) |