NTC Stromerzeuger 14 kVA, 400/230 V, Honda-Motor, E-Start

Description

Features

  • Honda GX 630 petrol engine with electric start
  • Connections: 1 × 400 V and 2 × 230 V
  • Compound voltage regulation
  • Open frame with access to all service points
  • Vibration isolation between the frame and the engine-generator unit

Technical data

ManufacturerNTC STAVEBNÍ TECHNIKA spol. s r.o.
Product typeGenerator, three-phase
Electrical output, 3-phase14,0 kVA
Electrical output, 1-phase4,0 kVA
Current, 3-phase / 1-phase20,0 A / 20,0 A
Voltage400 V / 230 V
Frequency50 Hz
Connections1 × 400 V + 2 × 230 V
Voltage regulationCompound
EngineHonda GX 630
Engine net power15,5 kW at 3.600 min⁻¹ (according to SAE J1349)
Electric startyes
Dimensions (L × W × H)1.060 × 660 × 600 mm
Weight114 kg
Quality managementISO 9001:2015
Country of manufactureCzech Republic

Product description

Three-phase generator with 14 kVA

The unit supplies both single-phase and three-phase loads, including circular saws and machines with what is known as a high starting load. The Honda petrol engine is started electrically.

Compound regulation – the key point

The manufacturer describes this as a particularly effective method of voltage regulation, especially for equipment such as compressors, water pumps and circular saws.

What is different about these loads: They have a high starting current. An electric motor draws several times its rated current when starting – depending on the design, five to eight times as much.

What happens with poor regulation: The voltage drops, the motor fails to get up to speed and, in the worst case, remains stalled – putting corresponding strain on the winding.

Compound regulation works differently: It uses the current flowing to strengthen the excitation field. The higher the load, the stronger the excitation – the generator counteracts the voltage drop.

Compound or AVR – the choice

NTC offers both types of regulation. The choice depends on the load.

Compound (this version)AVR
Strengthhigh starting currentsconstant voltage
Suitable forcompressors, pumps, circular saws, compactorselectronics, chargers, sensitive equipment
Response to load peaksincreases excitationadjusts afterwards
Voltage accuracyadequatehigher

The rule of thumb when advising customers: If you are running machines with motors, choose Compound. If you are powering electronics – control systems, chargers, measuring equipment – choose AVR.

The same output level is available in an AVR version – with the same engine and weight.

14 kVA three-phase, but only 4 kVA single-phase

This is the point most often overlooked.

Three-phase (400 V)14,0 kVA at 20,0 A
Single-phase (230 V)4,0 kVA at 20,0 A

Why the single-phase figure is so much lower: The generator produces three phases. A 230 V load is connected to just one of them – the other two remain unused.

What this means: If you mainly run 230 V equipment, you only get 4 kVA from a 14 kVA unit. For single-phase use only, a single-phase generator would be a more suitable and cheaper choice.

This unit is worthwhile when you have genuine three-phase loads – circular saws, concrete mixers, pumps and hoists.

The Honda GX 630

The engine delivers 15,5 kW at 3.600 min⁻¹ according to SAE J1349.

Why the engine output is higher than the electrical output: 14 kVA electrical output corresponds to around 11 kW of active power at a typical power factor. The remainder is accounted for by generator losses and the reserve for starting peaks.

Why the GX series is a good choice: It has been widely used in the construction industry for decades – spare parts, servicing and wear parts are readily available nationwide. For a unit used on different building sites, this is a real advantage over niche engines.

Electric start

The unit is started using a starter motor, unlike the smaller models in the range.

Why this is necessary at this size: A V-twin engine of almost 700 cm³ is difficult to start by hand and requires considerable effort. In cold weather and after being left unused for a long time, this becomes a real ordeal.

For hire companies and businesses with different operators electric start is the more practically important feature: if it is easy to start, it will be used.

Vibration isolation

A flexible connection is fitted between the frame and the engine-generator unit.

What it does: It reduces the vibration transmitted to the supporting surface.

Why this is more than just a comfort feature:

  • The unit stays in place. A generator mounted rigidly can move noticeably across the floor over several hours.
  • Less material fatigue in the frame and welds.
  • Less strain on the connections and internal wiring.
  • Quieter – vibration on concrete creates structure-borne noise.

The open frame

This design has been chosen deliberately.

What it does: All service points are accessible – oil drain, air filter, spark plugs and fuel tap.

Why this matters on building sites: A generator used on site operates in dusty conditions and under continuous load. Air filter cleaning and oil changes are not annual maintenance tasks, but regular jobs – anything that is difficult to access is likely to be neglected.

The frame also provides handling points and protects the unit during transport and manoeuvring.

The connections

ConnectionQuantityTypical loads
400 V1circular saw, concrete mixer, pump, hoist
230 V2hand tools, lighting, compactor

In practice, this means: The main machine runs via the three-phase connection, while two 230 V devices can be used at the same time – as long as the single-phase output does not exceed 4 kVA.

114 kilograms – plan for transport

At 1.060 × 660 × 600 mm, the unit cannot be carried by one person.

What this means: You should have a solution for transporting and moving the unit around the building site. The manufacturer offers a wheel kit as an option – an obvious addition if the unit is used at different locations.

Available options

OptionBenefit
Wheel kitMoving around the building site
Circuit breakerOverload protection
VoltmeterVoltage monitoring
Hour meterMaintenance intervals, hire billing
Automatic START-STOP panelEmergency power function in the event of a mains failure
Metal fuel canspecifically for GX 630 and GX 690

The START-STOP panel is the most interesting option: It starts the generator automatically in the event of a mains failure and stops it when the mains supply returns. This turns the building-site generator into an emergency power supply – a separate use case for businesses with critical equipment.

Applications

Building sites without a mains connection, construction companies and tradespeople, event technology, agriculture and forestry, local authorities and public works depots, emergency power supply, equipment hire, mobile workshops.

Operating notes

  • Note the single-phase output of 4,0 kVA – it is significantly lower than the three-phase output.
  • Take account of the starting currents of connected equipment; motors draw several times their rated current.
  • Only operate outdoors or in well-ventilated areas – combustion engines produce exhaust gases containing carbon monoxide.
  • Do not set up in enclosed spaces, cellars or garages.
  • Set up on level, load-bearing ground and secure against slipping.
  • Keep away from combustible materials.
  • Refuel only when the engine is switched off and cool, away from sources of ignition.
  • Protect electrical connections from moisture; check cables for damage.
  • When using as a standby power supply, observe the requirements for disconnection from the mains – feeding power back into the mains is life-threatening.
  • Check the oil level before each use; follow the engine manufacturer's maintenance intervals.
  • Clean the air filter more frequently when operating in dusty conditions.
  • For prolonged storage, drain the fuel or add a stabiliser.
  • Follow the manufacturer's operating instructions.

Frequently asked questions

How much power do I get in single-phase mode?

4,0 kVA at 230 V. The 14,0 kVA rating applies only to three-phase loads – a 230 V device is connected to just one of the three phases.

What is Compound regulation?

A voltage regulation system that uses the current flowing to strengthen the excitation field. The higher the load, the stronger the excitation – particularly effective for compressors, water pumps and circular saws with high starting currents.

Compound or AVR – which is better?

It depends on the load. Compound is for machines with motors and high starting currents; AVR is for electronics and equipment that needs a constant voltage.Both versions are available in this output class.

What connections does the unit have?

One 400 V connection and two 230 V connections.

Does the unit have electric start?

Yes. Electric start is practically essential for an engine of this size – starting it by hand would require considerable effort.

How heavy is the generator?

114 kg, with dimensions of 1.060 × 660 × 600 mm. A wheel kit is available as an option.

Can I use the unit as an emergency power supply?

With the optional automatic START-STOP panel, the generator starts automatically in the event of a mains failure. The requirements for disconnection from the mains must be observed.

Which engine is fitted?

A Honda GX 630 with an output of 15,5 kW at 3.600 min⁻¹ according to SAE J1349. The GX series is widely used in the construction industry – spare parts and servicing are readily available nationwide.

Properties
Drive type: Benzinmotor
Engine manufacturer: Honda
Gerätetyp : Stromaggregat
Maximalleistung: 14 kVA
Spannungsregelung AVR: ohne
Startsystem : Elektrostart
Stromart: 3-phasig (400 V)