Skip to main content Skip to search Skip to main navigation

Menu

MOBIFIxx 35 l/min-9.2 gpm 24 V DC tap-off terminals+ASA+EST 23405002

Description

MOBIFIxx 35 l/min-9.2 gpm 24 V DC tap-off terminals+ASA+EST 23405002

Technical data

Automatic start-up After switching on, the motor starts up with a delay

Automatic switch-off 1 The motor is switched off fully automatically when the valve is closed

Automatic switch-off 2 In the event of dry running, the motor is switched off fully automatically

Operating range (V) 23-25

Connection cable with tapping terminals, length (m) / (ft) 3 / 10

Connection on suction side G 1'' i

Connection on pressure side G 1'' i

Hydraulic data

Pump type Vane pump, self-priming

Delivery rate with free discharge up to (l/min) / (gpm) 35 / 9.2

Suction head up to (m) / (ft) 3 / 10

Delivery pressure up to (bar) / (psi) 1.6 / 23.2

Pumped media Heating oil and diesel fuels

Motor data

Insulation class F

Maximum permissible limit temperature (°C) / (°F) 155 / 311

Voltage (V) 24 V DC

Current consumption (A) 11

Power (W) 270

Fuse (A) 25 A plug-in fuse

Duty cycle with free outlet max. (min) 180

Running time (min) with closed dispensing valve max. 2

Torque (Nm) 0.45

Speed (rpm) 3000

Design IMB 5

Protection class IP66

Materials of wetted parts

Seals FKM (Viton®)/NBR

Pump housing AlSi 12 (seawater-resistant)

Rotor GG 25

Vane POM

Dimensions LxWxH (mm) / (inch) 270 x 120 x 120 / 10.6 x 4.7 x 4.7

Weight (kg) / (lb) 5 / 11

Specification

Vane pump with integrated bypass

Switch-off electronics with relay circuit

On and off switch

Fuse

Radio interference suppression motor

Siphon protection in accordance with WHG (Water Resources Act), permanently effective

Installation of flow meter NUMERIxx³, three-digit, possible (23 192)

Special features

First-class electric machine and pump construction

Continuous operation - 3 hours - with open valve

Delayed start-up after switching on the pump

Fully automatic switch-off when the valve is closed

LED fault indicator

Overvoltage and undervoltage protection

Lapped shaft ring seal set

Encapsulation of the electric motor, which largely prevents the formation of condensation that causes short circuits in the event of large temperature fluctuations

Pump housing can be freely positioned in all 90° positions

Switch housing can be freely positioned in all 90° positions

Switch housing in impact-resistant die-cast zinc coated by means of cataphoresis

Pump housing made of seawater-resistant die-cast aluminium, coated using cataphoresis

Motor housing completely galvanised, exterior coated

Tight tolerances ensure high suction and pressure performance with optimum efficiency

The material pairing vane - stator guarantees dimensional stability of the vane up to 200 °C / 392 °F

Low weight and exceptionally long service life due to choice of material