Skip to main content Skip to search Skip to main navigation
Menu

Battioni Pagani Vacuum pump MEC II 11000 G LF DX D80, 11137 l/min

Description
Series/model:

MEC

Drive:

Gear wheel

Direction of rotation:

right

Capacity (l/min.):

11137

Connection (mm):

80

Version:

MEC II 11000 G LF DX D80 LONG LIFE

Additional information:

Abbreviations:
LF: forced lubrication
LA: automatic lubrication
SX: anti-clockwise rotation
DX: clockwise rotation
STD: standard vane
Longlife: heat-resistant vane

NORMAL LUBRICATION
Lubrication takes place only during the intake phase. The vacuum created in the rotary vane vacuum pump draws oil from the tank. During the compression phase, lubrication is provided by the residual oil from the preceding phase. Normal lubrication is used only on models MEC 1000 and MEC 1600, which are manufactured exclusively with this type of lubrication.

FORCED LUBRICATION (LF)
This is the standard version for slurry tankers. Lubrication takes place during both the intake and compression phases, using a gear pump fitted at the rear and driven by the rotor shaft. The gear pump draws oil from the tank and feeds it to the manually adjusted metering tap. Excess oil flows back to the tank from the tap through a hose.

AUTOMATIC LUBRICATION (LA)
With this system, lubrication takes place during both the intake and compression phases using an adjustable-output metering piston pump fitted at the rear and driven by the rotor. Oil is injected directly into the rotary vane vacuum pump, eliminating the need for manual adjustment and ensuring significant oil savings.

Features of B&P vacuum pumps

M
The drive shaft (PTO) is driven via a cardan shaft at 540 rpm. This version can be identified by the gearbox housing at the front of the rotary vane vacuum pump, as well as by the identification plate and the marking on the upper housing section.

MA
The drive shaft (PTO) is driven via a cardan shaft at 1000 rpm. This version can be identified by the gearbox housing at the front of the rotary vane vacuum pump, as well as by the identification plate and the marking on the gearbox housing cover.

P
The drive shaft (PTO) is driven by a pulley and belt. This version can be identified by the cylindrical splined drive shaft and the identification plate: .... / P = pulley fitted.

D
The drive shaft (PTO) is driven via a cardan shaft connected directly to the press-fitted coupling. This version can be identified by the press-fitted coupling at the front of the rotary vane vacuum pump, as well as by the identification plate: .... / D = direct coupling.

H
The drive shaft (PTO) is driven by a hydraulic gear motor. This version can be identified by the hydraulic motor mounting at the front of the rotary vane vacuum pump, as well as by the identification plate: .... / H = hydraulic power transmission.

HM
With gearbox for drive by hydraulic motor.

G
This version of the rotary vane vacuum pump is fitted to the GARDA or LEDRA unit; it cannot be used on its own. The version can be identified by the external pinion at the front of the rotary vane vacuum pump and by the identification plate: ... / G = equipment for GARDA or LEDRA.

GA
This version of the rotary vane vacuum pump is fitted to the GARDA or LEDRA unit at 1000 rpm; it cannot be used on its own. The version can be identified by the external pinion at the front of the rotary vane vacuum pump and by the identification plate: ... /GA = equipment for GARDA or LEDRA at 1000 rpm.

K
The drive shaft (PTO) is driven via a cardan shaft at 540 rpm and is designed to drive a Group 2 or Group 3 pump. This version can be identified by the hydraulic pump mounting and the identification plate.

KA
The drive shaft (PTO) is driven via a cardan shaft at 1000 rpm and is designed to drive a Group 2 or Group 3 hydraulic pump. This version can be identified by the hydraulic pump mounting, the identification plate and the marking on the upper housing section.

BALLAST
Cooling by air injectors during intake. Continuous pump operation is possible at -0.7 bar. BALLAST pumps are supplied as standard with heat-resistant vanes. Crash Protection System – thanks to the elongated holes, the rotor drops down if it becomes blocked. This minimises the risk of the housing breaking. Heat indicator.

Lubrication system:

Forced lubrication

Pressure relief safety valve:

2"

Vacuum valve:

1 1/2"

Warning:

Before commissioning, fill the compressor with oil 4055070200100 or 21088898 GEB5 and the gearbox housing with oil 210CLP460 GEB20.

Compressor supplied without safety valves!

Every pump undergoes a comprehensive final inspection at the factory, during which the vacuum, compression and lubrication are checked, among other things.
A test report is produced for each pump and includes the pump’s serial number.

Weight:

10 g

Properties
Artikelart: Gerät / Maschine, Vakuumpumpen
Baureihe : MEC
Capacity (l/min.): 11137, 11137 l/min
Connection (mm): 80
Direction of rotation: rechts, Right
Drive type: Zahnrad
Gerätetyp : Vakuumpumpe
Passend für:: Battioni Pagani
Product group: Pumpentechnik
Pump type: MEC
Schmiersystem: Zwangsschmierung
Schmiersystem : Zwangsschmierung (LF)
Series/Model: MEC
Unterdruckventil: 1 1/2"
Version: MEC II 11000 G LF DX D80 LONG LIFE
drive: Zahnrad
Überdruck Sicherheitsventil: 2"